MGS Installation and Operation Manual
6 1000-0085 Rev 0
1.2. Technical Specifications
Specification Description
Power Supply 12-24 VDC, 12-24 VAC 50/60 Hz, 2 W max.
Power consumption (12V): 60mA (EC), 153mA (SC), 136mA (IR)
Visual Alarm Red LED
Fault Monitoring Red LED (on); Green LED (off)
Analogue Outputs 4-20 mA; 0-5 V; 0-10 V; 1-5 V; 2-10 V
Relay (Digital) Outputs 1 relay rated 1 A @ 24 VAC/VDC; Delay: 0, 1, 5, or 10 minutes
IP41 (standard); IP66 (optional)
Temperature Rating
Sensor Standard Housing IP66 Housing
IR (all)
-20° to 50° C -40° to 50° C
SC (all)
-20° to 50° C -40° to 50° C
EC (all but NH
3
)
-20° to 40° C -20° to 40° C
EC (0-1K ppm NH
3
)
-20° to 40° C -40° to 40° C
Humidity Rating
0-95% non-condensing
Dimensions/Weights per
Enclosure Type (see Note
below)
IP41 (standard) 86 x 142 x 53 mm 180 g
IP66 (optional) 175 x 165 x 82 mm 629 g
w/ Splash Guard 175 x 225 x 82 mm 700 g
w/PRV Sensor Head 175 x 155 x 82 mm 830 g
w/ Airflow/Duct 175 x 125 x 82 mm 578 g
Exd (ATEX only) 140 x 180 x 90 mm 2234 g
UL 61010-1, CSA C22.2 No. 61010-1, IEC 61010-1, EN 61010-1,
EN 55011, EN 50270, FCC Part 15, Subpart B, WEEE RoHS EuP
NOTE: The hazardous area Exd Gas Monitor products are
designed with individually certified Exd main housing enclosures and
certified Exd remote or attached sensor enclosures. The main
housing enclosure and its PCB assembly are also Exd certified, but
the final Exd Gas Monitor assemblies (main enclosure and/or
sensor assembly) are not currently Exd certified, but are pending
additional testing.